Parameter Settings (TG-5122)


PARAMETER SETTINGS

TG-5122


         Check Date:  06.09.19   

INVERTER NAME: YASKAWA

MODEL: CIMR-LB4A0031FAC 

POWER: 15 kw. 3-Phase/400 Volt





  • Language Selection:

  A1-00------------------07 (Chinese).

  • Access Level Selection:

  A1-01----------------------0002 (Advance Access).

  • Control Method Selection:

  A1-02------------------00 (V/F Control).

  • Speed Reference Selection:

  b1-01----------------------------00 (Digital Operator).


  • Up/Down Command Selection:

  b1-02------------------=-------------01 (Digital Input Terminals).

  • Phase Order Selection:

  b1-14----------------------------00 (U-V-W).

  • Acceleration Ramps:

  C1-01-------------------- 001.50 m/sec.

  • Deceleration Ramps:

  C1-02-------------------- 001.50 m/sec (1st Deceleration Time).
  C1-03-------------------- 001.50 m/sec (2nd Deceleration Time).



  • Jerk Settings:

  C2-01----------- 00.50 m/sec.
  C2-02----------- 00.50 m/sec.


  • Carrier Friquency:

  C6-03------------------ 08.0 Hz.

  • Speed Reference:

  d1-01---------------- 020.00 Hz (High Speed).
  d1-02---------------- 010.00 Hz (Slow Speed-1).
  d1-03---------------- 000.00 Hz (Slow Speed-2).

  • No Load Maximum Current-I :

  Up To Down ------------------------20 Amp.
  Down To Up ------------------------15 Amp.

  • No Load Minimum Current-I :

  Up To Down ------------------------10 Amp.
  Down To Up ------------------------10 Amp.



Check By: Real (37987)





No comments