Parameter Settings (TG-87718)
PARAMETER SETTINGS
TG-87718
Check Date: 21.09.19
INVERTER NAME: YASKAWA
MODEL: CIMR-LT40031FAA
POWER: 15 kw. 3-Phase/400 Volt
- Language Selection:
A1-00------------------00 (English).
- Access Level Selection:
A1-01----------------------0002 (Advance Access).
- Control Method Selection:
A1-02------------------03 (Closed Loop Vector Control).
- Speed Reference Selection:
b1-01----------------------------00 (Digital Operator).
- Up/Down Command Selection:
b1-02------------------=-------------01 (Digital Input Terminals).
- Phase Order Selection:
b1-14----------------------------00 (U-V-W).
- Acceleration Ramps:
C1-01-------------------- 01.80 m/sec.
- Deceleration Ramps:
C1-02-------------------- 01.80 m/sec (1st Deceleration Time).
C1-03-------------------- 01.80 m/sec (2nd Deceleration Time).
- Jerk Settings:
C2-01----------- 01.50 m/sec.
C2-02----------- 01.00 m/sec.
- Carrier Frequency:
C6-03------------------ 06.0 Hz.
d1-01---------------- 000.00 Hz (High Speed).
d1-02---------------- 000.00 Hz (Slow Speed-1).
d1-03---------------- 000.00 Hz (Slow Speed-2).
Up To Down ------------------------20 Amp.
Down To Up ------------------------18 Amp.
Up To Down ------------------------ Amp.
Down To Up ------------------------ Amp.
- Speed Reference:
d1-01---------------- 000.00 Hz (High Speed).
d1-02---------------- 000.00 Hz (Slow Speed-1).
d1-03---------------- 000.00 Hz (Slow Speed-2).
- No Load Maximum Current-I :
Up To Down ------------------------20 Amp.
Down To Up ------------------------18 Amp.
- No Load Minimum Current-I :
Up To Down ------------------------ Amp.
Down To Up ------------------------ Amp.
Check By: Real (37987)