Parameter Settings (TG-5124)


PARAMETER SETTINGS

TG-5124


         Check Date:  06.09.19   

INVERTER NAME: YASKAWA

MODEL: CIMR-LB4A0039FAA 

POWER: 18.5 kw. 3-Phase/400 Volt



  • Language Selection:

  A1-00------------------07 (Chinese).


  • Access Level Selection:

  A1-01----------------------0002 (Advance Access).


  • Control Method Selection:

  A1-02------------------02 (Open Loop Vector Control).


  • Speed Reference Selection:

  b1-01----------------------------00 (Digital Operator).


  • Up/Down Command Selection:

  b1-02------------------=-------------01 (Digital Input Terminals).


  • Phase Order Selection:

  b1-14----------------------------00 (U-V-W).


  • Acceleration Ramps:

  C1-01-------------------- 000.90 m/sec.


  • Deceleration Ramps:

  C1-02-------------------- 001.00 m/sec (1st Deceleration Time).
  C1-03-------------------- 001.50 m/sec (2nd Deceleration Time).



  • Jerk Settings:

  C2-01----------- 01.50 m/sec.
  C2-02----------- 01.20 m/sec.



  • Carrier Friquency:

  C6-03------------------ 13.0 Hz.


  • Speed Reference:

  d1-01---------------- 018.00 Hz (High Speed).
  d1-02---------------- 009.00 Hz (Slow Speed-1).
  d1-03---------------- 025.00 Hz (Slow Speed-2).


  • No Load Maximum Current-I :

  Up To Down ------------------------65 Amp.
  Down To Up ------------------------20 Amp.


  • No Load Minimum Current-I :

  Up To Down ------------------------25 Amp.
  Down To Up ------------------------11 Amp.



Check By: Real (37987)